CGLN1 - London

This facility acts as ColocationGuard’s gateway to both the developed and emerging markets of Europe. It is also located at its London offices just off Silicon Roundabout in the East End of London.

Facility Features

  • Managed Meet-Me Rooms (MMR)
  • Mission Critical Security
  • Global Hubs
  • Cloud Components
  • Mission Critical Security
  • Expert Engineers
  • Accelerate Service Delivery
  • Multiple levels of Managed Services
  • HIPPA, SSAE16 Type 2 & SOC2, PCI Compliance
  • Migration Planning
  • Capacity planning
  • Customer-centric support 24x7x365

Exceptional Experience Every Time

Get Quote Call Us Now: 1-888-342-0598

SPECIFICATIONS

Space
  • Total area of co-location facility: 11000 sq ft.
  • Total number of racks: 300 approximately
  • Rack mix:600x1000x2200mm-19”rack–quarter, half and full racks available
Monitoring
  • EMS system monitors temperature and humidity, water detection, UPS, fire alarm panel, air conditioning and two generators
  • EMS server located in secure MMR IT cabinets
  • Front end located SNMP management system accessible by ColoGuard 24/7 SMC (Service Management Centre)
Security
  • ColoGuard Global Hubs is a 24/7 manned co-location facility
  • Field manager and security team are present during working hours from 8am to 6pm
  • Access is controlled by SMC during out of hours
  • Access to Telephone House is controlled 24/7by the Telephone House security team located at the reception of the building
  • Access to the colocation facility is controlled by ColoGuard staff and network operations centre
  • All Colocation areas and entrances are monitored via CCTV with management stations resident in the SMC
Power
  • Non-essential PDU providing power to: A/C air handling units
  • Dual diverse AC power distribution with 32 Amp C-form sockets (Commando)
  • COLO 1 & 2 supported by a 1000kVa diesel generator at 415 Volts, 3 phase, weatherproof and acoustic ISO 20ft container
  • COLO 3 supported by a 450kVA diesel generator at 415 Volts , 3 phase, weatherproof and acoustic ISO 16ft container
  • 1000kVA Generator - 2500 litre bundled fuel tank
  • 450kVA Generator - 750 litre bundled fuel tank
  • 8 hour contracted re-fuelling response SLA
Connectivity
  • Managed Meet-Me Rooms (MMR)
  • Access global data centre facilities with fully managed
  • MMR for redundant cable routing and easy traceability
Other
  • VESDA re detection in computer rooms and plenums
  • C Class re extinguishers as per regulatory requirements
  • COLO 1 & 2 FM200 re suppression system is installed in computer room and plenums
  • COLO 3 IG-55 re suppression system is installed in computer room and plenums
Cooling
  • N+1 built-in redundancies
  • Hot aisle/cold aisle structure with cold aisle containment
  • Air delivery to systems at 23 Degree Celsius db
  • Air relative humidity at 45%